Dynamic/Static Ionic Contamination Tester Usage
The instruments are suitable for the ion contamination levels testing of bare PCB board as well as PCBA before and after cleaning and coating processes.
Dynamic/Static Ionic Contamination Tester Characteristic
l Precise :
Adopting online high-precision conductivity meter, fully enclosed circulatory system, mixed anion and cation exchange resins, as well as real-time processing algorithms and temperature compensation technology.
l Efficient
Adopting heat extraction and high-speed loop flushing technology.
l Characteristic
Unique dynamic / static test mode.
l Customize
Volume can be customized according to the requirements.
Dynamic/Static Ionic Contamination Tester Technical Parameters
Item | LZ22 |
Test Method | Static/Dynamic testing |
Test Accuracy | ±5% |
Resolution of Conductivity | 0.001us/cm2 |
Electrode Resolution Range | 0.0001us/cm2~20 us/cm2 |
Measuring Circuit Board Area | 1000-4200cm2 |
Efficiency | 5~15 minutes every time |
Proportion of Extract | 0.85~0.855 |
Reference | 66/100MΩ |
Volume of Water Tank | 352mm×70mm×600mm(L×W×H) about 17L |
Machine Size | 1050mm×600mm×920mm(L×W×H) |
Power | 1300W |
Power Requirement | AC220V 50HZ |
Machine Weight | 115Kg |
Working Environment Temperature | 22ºC±3ºC |
Working Extract Temperature | 40ºC±2ºC |