Gc9802 Residual Solvent Testing Gas Chromatography Face Mask Testing Machine

GC9802  Residual Solvent Testing Gas Chromatography  face mask testing machineFunction:Gas chromatography carries out the quantitative analysis and peculiar smell testing for residual solvent on food packaging cases after printing;Test the pureness and quality of organic solvents.Techinical ParameterItemGC 9801Hydrogen

Featured Products

GC9802  Residual Solvent Testing Gas Chromatography  face mask testing machine

Function:

Gas chromatography carries out the quantitative analysis and peculiar smell testing for residual solvent on food packaging cases after printing;

Test the pureness and quality of organic solvents.

Techinical Parameter

Item

GC 9801

Hydrogen flame ionization detector (FID)

M≤1×10-11 G/S

Thermal conductivity detector (TCD)

S≥5000mv.ml/mg (benzene)

Electron capture detector (ECD)

M≤2×10-13g/ml (r-666)

Flame-photometric detector (FPD)

Ms≤5×10-11g/sec (thiophene) Mp≤1×10-11g/sec (1605)

Nitrogen and phosphorous detector (NPD)

Mn:1×10-13g/sec    Mp:1×10-13g/sec

Temperature

10~400°C

Temperature percision

≤0.1°C

Temperature rise speed

0.1~40°C/min

Features:

1.With higher ratio of function and reasonable price, economic and efficient

2.The design of the cellular integral structure is convenient for installation.

3.It can be connected to the chromatogram data work station so as to greatly improve the working efficiency.

4.With FID detector

5.With the flexible design of the packed column and capillary column injection ports.

6.Packed column and capillary column sample injectors can be selected as per actual situations. Wide column box (300×300×200mm)

7.In order to meet complicated analytic task, it makes use of various chromatographic columns so as to offer convenience and widen the range of the analytic samples. The advanced noise suppression system can fully eliminate the fan noise under the chromatogram working state, so as to provide you a comfortable and quiet working atmosphere.

8.The sampling device is completely vitrified with two modes of rapid vaporizing and column sample injection.

9.Bran-new pressure stabilization and various air circuit system

10.The air circuit has three different kinds of forms: Single, double and triple. It can match six-way valve, blow back, and precut equipment and so on according to the users' demands. It adopts new type pressure regulation system to ensure the re-productivity of equipment.

11.Reforming furnace can be equipped to implement microanalysis of CO and CO2.

12.Cracking furnace can be equipped to do double eight-step temperature rise with microcomputer control, man-machine conversation and simple application.

13.Advanced temperature control system

14.Adopt microcomputer control and man-machine conversation to indicate various needed temperatures of the temperature column box.

15.Column box temperature control scope: (room temperature +10°C) - 400°C, eight-step temperature rise.

The speed is 0 - 30°C/min (increase 0.1°C/min), and the temperature control precision is 0.1%.

The control point number is eight points of A type with control scope (room temperature +10°C) - 400°C.

16.Overheat protection function

It can freely set temperature within 400°C with software program protection, and the hardwired connection adopts dual fail-safe design




Gc9802 Residual Solvent Testing Gas Chromatography Face Mask Testing Machine
Gc9802 Residual Solvent Testing Gas Chromatography Face Mask Testing Machine
Gc9802 Residual Solvent Testing Gas Chromatography Face Mask Testing Machine
Gc9802 Residual Solvent Testing Gas Chromatography Face Mask Testing Machine
Gc9802 Residual Solvent Testing Gas Chromatography Face Mask Testing Machine
 